Water hardness meter
Category: other lab apparatus  Publish Time: 2022-10-05 03:14 

Water hardness meter
YD300

YD300 Portable Water Hardness Meter

 

Portable meter for measurement of water hardness by electrode measurement method, suited in field and on site.

Introduction

 

Portable meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage, low voltage display, etc.
Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca). Three options of three units : ºfH(France),ºdH (Germany)and ºeH(UK)from WH-Link communication software.
Equipped with B1,B2 and B3 calibration solution.
IP57 waterproof rating, equipped with portable case, calibration solution and other accessories.

 

Specifications

 

Water Hardness
Measuring range
 
 
 
Resolution
Accuracy
Temp. compensation
Calibration Solution
 
 
 
Calibration Mode
(0 ~ 10)mmol/L;        (0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO);    (0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler);  (0 ~ 70)ºeH (England Degree).
0.01 and 0.1 water hardness units
±5% FS
(5 ~ 50)℃((automatic))
B1 Calibration Solution — 2.00×10-2 mmol/L
B2 Calibration Solution — 2.00×10-1 mmol/L
B3 Calibration Solution — 2.00 mmol/L
(B3Calibration Solution also can be used for the soaking solution of electrode)
(a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.
(b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality.
Temperature
Measuring range
Resolution
Accuracy
0 ~ 60℃
0.1℃
±0.5℃
Other Technical Parameter
Data storage

Content Storage

 

Power

Dimension and weight

Quality & safecertificate

99 groups

serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.

Two AA cells(1.5V×2)

Meter:(65×120×31)mm/180g; Carry Case: (255×210×50)mm/790g

IISO9001:2000 and CE

working conditions
Ambient temperature
ambient humidity
(5~35)℃
≤85%RH

 

Standard Kit Includes

 

1. Model YD300 water hardness meter

1set

2.Model 601-S water hardness electrode( With two measruing heads and one screw plug )

1pc

3. AA cell (1.5V )

2pcs (included)

4.100mL hardness calibration solution ( B1, B2 and B3 )

1btl/each

5.20mL test cup

6pcs

6. Test cup pedestal

1pc

   
   
7.Carring case

1pc

8. Operation manual

1 set

 

Optional Accessories

 

Accessory Category

Description

Specification

Water hardness electrode

601-S water hardness electrode

Suited for measurement of total concentration of calcium ion and magnesium ion, match YD300 meter, 8 pin connector

 